HOME ] UP ] FEEDBACK ] CONTENTS ] SEARCH ]
NC-2 Nitrogen Controller

[ NC-2 Nitrogen Controller ] QDN-1200-6 Nitrogen Cabinet ]
SITE LINKS

 

 

ACE Dragon Corporation

ACE Dragon Corp. - Dr. Storage

DESCRIPTION 

NC-2 digital nitrogen controller is used to control the filling of dry air into the cabinet. So the desired relative humidity in the nitrogen cabinet/nitrogen box can be reached. For example, if 5%RH is the required condition, then the dry air will stop to fill when <5%RH is reached. The dry air can be nitrogen, CO2 or inert gas. However, nitrogen is the most frequently used dry air for a nitrogen cabinet/nitrogen box. Traditional nitrogen cabinet/nitrogen box allows the N2 to fill all the time continuously. After NC-2 Nitrogen Controller is adapted, 70~90% of N2 can be saved right away.

MODEL NC-2 NITROGEN CONTROLLER  SPECIFICATION  


  NC-2 Nitrogen Controller

bullet

Operation Range: -20~60C, 0~99%RH

bullet

Precision of Temperature Sensor: 1.0C

bullet

Precision of Humidity Sensor: 3%RH
Resolution of Temperature: 0.1
C

bullet

Resolution of Humidity: 0.1%RH

bullet

Nitrogen Controller Dimension: W220*D160*H70mm

bullet

Nitrogen Controller Weight: 1.8kgs

bullet

Nitrogen Controller Power: 110V/230V (select voltage in advance)

INFORMATION   
 Ace Dragon/ Dr. Storage Catalogue
to How to select a dry cabinet
STANDARD FEATURES  
Energy Saving: Dry air will no longer fill continuously. It consumes only 20W/hour while the filling solenoid of NC-2 is activated.
Easy to install: Any traditional nitrogen cabinet can be upgraded by adding NC-2 within 20 minutes. Huge waste of nitrogen can be saved permanently.
Sensor Calibration reminding: NC-2 can be connected to a PC through intranet network (option). All of the data of temperature and relative humidity will be recorded and the fluctuation will be shown in the graph.
Data Recording: It is important to verify that the condition of storage meets the regulation of
J-STD-033B. All NC2s are equipped with Humidity Manager V2 software for this application. The users can connect notebook PCs directly to the RS232 port of NC-2 to acquire the data or use our data logger to record the data through our software. With our data recording function, the historical fluctuation of relative humidity and temperature can be shown clearly in the graph. The floor life of the Moisture Sensitive Devices can also be calculated in the software . This uniquely patented function can easily verify if the SMD packages are stored at proper condition. It is very convenient for those who carry out quality assurance procedures.

HOME ] UP ]
Send mail to info@bita.se with questions or comments about this web site.
Copyright 1998 BITA ELEKTRONIK SVENSKA AB 
Last modified: 2016-08-22