DESCRIPTION 

QDN Series Nitrogen dry cabinet is a plug and play, fully auto-dry cabinet which stables the cabinet condition at 1%RH. There is no need to set the panel buttons at all. It is specially designed for moisture sensitive SMD packages to comply with J-STD-033B.

MODEL

QDN-1200-6

QDN-600

QDN-1200-6-SS

QDN-600-SS

Humidity Range

1%RH

Precision/Accuracy

3.0%RH, 1C

Display Precision

 1C, 3%RH

Recovery time (Open door 30 secs)

Open door 30 seconds and close, 15 mins recovery time to <5%RH, 30 mins recovery time to <2%RH

Voltage

230 Volt

External dimensions (mm)

W1200xD672xH1820

W600xD672xH1820

W600xD672xH1274

W600xD672xH632

Internal dimensions (mm)

W1198xD645xH1618

W598xD645xH1618

W598xD645xH1071

W598xD645xH524

Shell dimensions (mm)

W1155xD530xH20

W555xD530xH20

W555xD530xH20

W555xD530xH20

Capacity

1250 Liter

624 Liter

413 Liter

202 Liter

No. of shelves

5

5

3

2

Power consumption

Ave. 135Wh
Max. 425W

Ave. 83Wh
Max. 285W

Ave. 83Wh
Max. 285W

Ave. 83Wh
Max. 285W

MODEL QDN-1200-6  NITROGEN DRY CABINET 


  Nitrogen Dry Cabinet Model QDN-1200-6

bullet

Humidity Range: 1%RH.

bullet

Color: black

bullet

Software: Humidity Manager V2 for drawing the curve of RH and temperature.

bullet

Structure: 1mm thick carbon steel with antistatic paint or stainless steel "-SS".

bullet

Door: Handles, airtight magnetic sealers and antistatic glass.

bullet

Wheel: four antistatic 3 wheels, two of them with brakes.

bullet

Grounding Wire: 1MΩ. (940mm long)

bullet

ESD Paint: 103~109Ω. (surface resistance)

PERFORMANCE 
CONTROL PANEL   EXTENDED BIN  
INFORMATION  
 Ace Dragon/ Dr. Storage Catalogue
to How to select a dry cabinet
 
OPTIONS 

  to Data Logger
  to LOG-S3.0 Humidity Manager V3
  to LOG-S2.1-T12 SensorLook V3

STANDARD FEATURES  
bullet

Flash and Buzz alarm; Built-in humidity and temperature alarm; upper and lowers limits can be set.

bullet

Built-in calibration reminding; world's first and only dry cabinet that complies with ISO standard. cleaning

bullet

PPS Heat resistant material;  Used on all dryers; 260C heat tolerance to avoid any deforming or melting of dryer.  

bullet

Built-in RS232 port to be used with our software for instant monitoring and graphing of condition inside the cabinet.

bullet

Computerized humidity management that replaced human recording; be aware of the condition inside the cabinet at all time.