HOME ] UP ] FEEDBACK ] CONTENTS ] SEARCH ]
RTC H-SERIES

Semiconductor ] Flat Panel Displays ] Microelectronics ] Solar Cell ] RTC S-SERIES ] RTC D-SERIES ] RTC EFC-SERIES ] RTC SMD-SERIES ] RTC AG-SERIES ] [ RTC H-SERIES ] RTC HT-SERIES ] RTC LA-SERIES ] RTC WB-SERIES ] RTC T-SERIES ] RTC TFA-SERIES ] RTC C-SERIES ] RTC PV-SERIES ] RTC PVD-SERIES ]
SITE LINKS

 

 

RADIANT TECHNOLOGY CORP.

RTC Home

RTC H-SERIES INFRARED FURNACES 

The H-Series combines all the necessary components for hydrogen operation with the normal operation of a furnace.  Special warm up and cool down procedures are implemented along with methods for preheating the hydrogen atmosphere as enters into the furnace interior.  Both entrance and exit baffles are included to generate an inert gas curtain which keeps ambient air from entering the furnace interior.  Excess hydrogen is directed into a burner assembly where it is mixed with ambient air and ignited, thus preventing the buildup of excess gas.

OPTIONS 

RTC H-Series Furnaces
RTC H-Series Furnaces
(click on picture to enlarge)

bullet Oxygen Analyzer
bullet Moisture Analyzer
bullet Hydrogen Operation, Hydrogen/Nitrogen Mixing
bullet Hydrogen Detector
bullet On-Screen Profiling
bullet Ultrasonic Cleaner with Optional Dryer
bullet Belt Brush Cleaner
bullet Air Purification System
bullet Air Filter Regulator
bullet Emergency Power Supply
bullet Uninterruptible Power Supply
bullet Element Monitor
bullet Conveyor Extensions
bullet Redundant Over Temperature Scanner/Shutdown
bullet Electrical Line Filter
bullet Low Range Belt Speed (0.5 to 10 in./min.) 
bullet RTC Software Program, PC/HOST Communications and Protocol
bullet Three Tier Process Ready/Alarm Light Tower
PRODUCT DATA SHEETS 
RTC H-Series Overview 
SPECIFICATIONS 
CONTROLLED ATMOSPHERE

COOLING

to less than 5 PPM Oxygen. Controlled atmosphere or air impingement.
CONVEYOR BELT WIDTH CONVEYOR BELT SPEED
Up to 58 inches. Up to 120" per minute.
ELECTRICAL POWER CONSUMPTION

EXHAUST SYSTEMS

6-60 KW typical. venturi-driven and flow meter controlled.
POWER SUPPLY HEATERS
200-240 volts, 3 phase, 50-60 Hz or 380-480 volts, 3 phase, 50-60 Hz. Tungsten filament in Halogen back filled quartz. Over temperature protection.
NORMAL OPERATING TEMPERATURE COMPUTERIZED CONTROL SYSTEM
125-1000C.. Cross-belt temperature uniformity: +/- 1.5C.. Class 100 cleanliness PLC with PC and user-friendly MMI control system and instrumentation, includes PID control, data acquisition, diagnostic capabilities and real-time remote operation.
CLEARANCE ABOVE CONVEYOR BELT
2 inches.

HOME ] UP ]
Send mail to info@bita.se with questions or comments about this web site.
Copyright 1998 BITA ELEKTRONIK SVENSKA AB 
Last modified: 2016-08-22