2 ZONE HVS 100 HIGH VACUUM SEALER  WITH GETTER ACTIVATION 

2 Zone High Vacuum Sealer for sealing of MEMS-Packages under high vacuum (up to 10exp.-6 hPa) with high reliability hermetically sealing. The electronic component can be processes before sealing in 2 heating zones with different temperatures up to 450 C. This allows also the getter activation. There can be processed 6 packages in parallel (maximum 6 adapters each with 14mm diameter).
The ramp up rate is significant with 35 K/min in vacuum. The PID controller allows the storage of up to 20 programs with 100 steps each. The USB interface allows the easy programming and storage of unlimited programs. The process data can be recorded and saved as .csv or .xls data.
A key feature is the automatically positioning and sealing of the parts, whereas both parts must have the same temperature. The control of different heat-up ramp rates and/or ramp-down rates has been a huge task which was solved excellent.
The open construction behind glass allows a continuous monitoring/viewing of the process.
The electrical connection is 3,2 kW (230V AC, 1 phase) and can be attached to a standard power socket.
Water cooling is strictly required for operation.
The small dimension with 200 x 500 x 470 mm (WxHxD) and the small weight of 23,5 kg makes the system very compact and allows the placement on a small laboratory table.
This system is perfect for small series and prototype production and is a low cost solution in comparison to other production systems.

TECHNICAL DATA  

HVS 100 HIGH VACUUM SEALER

HVS 100 HIGH VACUUM SEALER

bullet

2 heated regions, each with 100 mm and 6 component adaptors

bullet

Chamber height 100 mm

bullet

Temperature range bottom heater: up to 450 C, top heater: up to 200 C

bullet

Bottom heater optional up to 600 C

bullet

Ramp up rate 35 K/min (in vacuum)

bullet

Ramp down rate 25 K/min (in vacuum)

bullet

Vacuum capable up to 10exp.-6 hPa incl. pump, gate valve and vacuum measurement

bullet

Interface USB incl. software UniSoft

bullet

Controller HVS-2604 (20 programs storable, each with 100 steps)

bullet

Dimensions 200 x 500 x 470 mm (WxHxD)

bullet

Weight 23,5 kg

bullet Voltage 230 V AC 1 Phase
bullet Frequency 50-60 Hz
bullet Current max. 16A
bullet Frequency 50-60 Hz
bullet Connected load 3,2 kW
DATA SHEET  
Get the UTP-DB2Z-HVS Datasheet in UniTemp HVS 100/200 HIGH VAKUUM SEALING
OPTIONS AND ACCESSORIES 

bullet

HVS-TC: Additional thermocouple to measure on device; for external measurement tool

bullet

WC I: Closed loop water cooling system (stand alone)

2 ZONE HVS 200 HIGH VACUUM SEALER  WITH GETTER ACTIVATION 

2 Zone High Vacuum Sealer for sealing of MEMS-Packages under high vacuum (up to 10-6 hPa) with high reliability hermetically sealing. The electronic component can be processes before sealing in 2 heating zones with different temperatures up to 450 C. This allows also the getter activation. There can be processed 6 packages in parallel (maximum 6 adapters each with 42 mm diameter).
The ramp up rate is significant with 20 K/min in vacuum. The PID controller allows the storage of up to 20 programs with 100 steps each. The USB interface allows the easy programming and storage of unlimited programs. The process data can be recorded and saved as .csv or .xls data.
A key feature is the automatically positioning and sealing of the parts, whereas both parts must have the same temperature. The control of different heat-up ramp rates and/or ramp-down rates has been a huge task which was solved excellent.
The open construction behind glass allows a continuous monitoring/viewing of the process.
The electrical connection is 11 kW (230/400V AC, 3 phase, +N) and can be attached to a standard power socket.
Water cooling is strictly required for operation.
The dimension with 550 x 500 x1060 mm (WxHxD) and the weight of 105 kg makes the system very compact and allows the placement on a laboratory table or can be integrated in a production line with automatic loading/unloading.
This system is perfect for series and prototype production and is a low cost solution in comparison to other production systems.

TECHNICAL DATA  

HVS 200 HIGH VACUUM SEALER

bullet 2 heated regions, each with 200 mm and 6 component adaptors
bullet Chamber height 100 mm
bullet Temperature range bottom heater: up to 450 C, top heater: up to 200 C
bullet Bottom heater optional up to 600 C
bullet Ramp up rate 20 K/min (in vacuum)
bullet Ramp down rate 20 K/min (in vacuum)
bullet Vacuum capable up to 10exp.-6 hPa, incl. pump,  gate valve and vacuum measurement
bullet Interface USB incl. software UniSoft
bullet Controller HVS-2604 (20 programs storable, each with 100 steps)
bullet Dimensions 550 x 500 x 1060 mm (WxHxD)
bullet Weight 105 kg
bullet Voltage 230/400 V AC, 3 Phase, +N
bullet Frequency 50-60 Hz
bullet Current max. 3x16A
bullet Connected load 11 kW
DATA SHEET  
Get the UTP-DB2Z-HVS Datasheet in UniTemp HVS 100/200 HIGH VAKUUM SEALING
OPTIONS AND ACCESSORIES 

bullet

HVS-TC: Additional thermocouple to measure on device; for external measurement tool

bullet

WC I: Closed loop water cooling system (stand alone)